Please note that if you flash your firmware AFTER configuring the device then you will need to go save your settings again, or manually enable it as described below.You can manually enable this setting by connecting to your AlarmDecoder and issuing the following command: CCOM=YWhile it's possible you could make things work without knowing the installer code for your panel, there are a number of things that may need to be changed in the panel programming.If your panel is currently or was previously monitored you'll likely need to either obtain the CSID and Account number for your panel or reset the dialer settings to factory default. VISTA 15P - Ademco 6 Zone.See the pictures to the right for examples.All of our devices are currently supported by the AlarmDecoder Modem.However, you do need to flash firmware version 2.2a.8.2 or later onto the AlarmDecoder.You can find the firmware downloads here.Do I need to change any settings on my AlarmDecoder?There is one new setting to enable communication with the panel: COM.Normally this is set by the AlarmDecoder Modem Configuration utility when you configure your device. You can determine the revision of your panel by again checking the panel circuit board for a chip & socket with a sticker on it.View and Download Honeywell VISTA 15P - Ademco 6 Zone Control Panel installation and operation manual online. Next, you need to confirm that the panel software revision meets the level required to support internet downloading.Run the AlarmDecoder Modem Setup from your Start Menu. One connection is allowed at a time unless you're using the network interface. Make sure that all keypad applications, terminal clients or other software accessing the AlarmDecoder is closed. (Shift + Right-click -> Run As Administrator) Run the installer as Administrator. Download the AlarmDecoder Modem software using the link provided in your order email or from.If Network: Fill in the name or IP address of the computer (or AD2PI) that's running the ser2sock service. If USB or Serial: Select the correct AlarmDecoder COM port. Select USB, Serial or Network to indicate the type and location of your AlarmDecoder device. You should make a note of this for later.
![]() ![]() Ademco Compass Software Revision MeetsSet the panel phone number to whatever you prefer. Select Ademco CIA 2400 as your modem type. Select Ademco/First Alert for the Company. Close the window and select the port in the list. Choose your AlarmDecoder Modem COM port from the list and click Add. Select the AlarmDecoder Modem COM port (from the first dropdown) as your COM port. Download united airline app for macUPLOAD retrieves the configuration from your panel and puts it into Compass®. The Account number in Compass® much match.Using Compass® is beyond the scope of this document, but one thing that should be noted is the definition of UPLOAD and DOWNLOAD.These are opposite from traditional logic since they are defined as if from Compass®' point of view at a alarm company. Acct # in Panel: Select this option if the Account number has been programmed on your panel. First Time Communication: Select this if your panel has a default CSID. Select the proper CSID setting for your install. Uncheck the Answering Machine Defeat checkbox. No reprogramming should be required.The CSID (Central Station ID) is the identifier that alarm companies use to authenticate with your panel. After you get the chip it's as simple as popping the old one out and putting the new one in. You can find replacement chips with newer firmware for a reasonable price on Ebay. You can download that from here.Check the revision of your panel by following the instructions here.It's a fairly simple process to swap the chip on your panel if the revision doesn't meet the minimum requirement. The following issues should be checked in the order they're presented, though the incorrect CSID is probably the most common issue.This features requires version 2.2a.8.2+ on your AlarmDecoder. All trademarks are the property of their respective owners. The dialer settings may be reset by using *96 in programming mode typically, but please consult your programming manual before doing so.Warning: If your alarm system is currently monitored you should note that changing your dialer settings (with *96 or otherwise) will potentially keep your alarm company from doing their job.No COM port available in the AlarmDecoder Configuration toolPlease email us at and we'll help you figure out what's going on.If you have issues with the software please feel free to email us at or post in our forums.Please include the following details with your request: You'll either need to obtain that ID from them or reset the dialer settings.
0 Comments
Leave a Reply. |
AuthorAngela ArchivesCategories |